|
|
Board Mount Current Sensors CURRENT SENSOR ( 60A; 15V)
- L18P060D15
- Tamura
-
1:
₡6 084,24
-
3 277In Stock
|
Mouser Part #
838-L18P060D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 60A; 15V)
|
|
3 277In Stock
|
|
|
₡6 084,24
|
|
|
₡5 126,58
|
|
|
₡4 767,46
|
|
|
₡4 325,07
|
|
|
View
|
|
|
₡4 023,20
|
|
|
₡3 461,09
|
|
|
₡3 435,07
|
|
|
₡3 044,72
|
|
|
₡2 982,27
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
60 A
|
|
0 Hz to 100 kHz
|
|
|
|
Current Sensors - Industrial 18V 120C 2500A
- L55S2T5D15M
- Tamura
-
1:
₡58 208,85
-
13In Stock
|
Mouser Part #
838-L55S2T5D15M
|
Tamura
|
Current Sensors - Industrial 18V 120C 2500A
|
|
13In Stock
|
|
|
₡58 208,85
|
|
|
₡45 181,60
|
|
|
₡43 245,47
|
|
|
₡40 825,31
|
|
|
View
|
|
|
₡40 101,86
|
|
|
₡39 654,26
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
|
2.5 kA
|
|
25 kHz
|
|
|
|
Current Sensors - Industrial 18V 120C 2000A
- L55S2T0D15M
- Tamura
-
1:
₡56 907,69
-
15In Stock
|
Mouser Part #
838-L55S2T0D15M
|
Tamura
|
Current Sensors - Industrial 18V 120C 2000A
|
|
15In Stock
|
|
|
₡56 907,69
|
|
|
₡49 095,50
|
|
|
₡45 618,79
|
|
|
₡40 419,34
|
|
|
View
|
|
|
₡39 904,08
|
|
|
₡39 362,80
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
Magnetic Proportion System
|
2 kA
|
|
25 kHz
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 300A;+5V;VREFOUT)
- L31S300S05FS
- Tamura
-
1:
₡8 306,63
-
400In Stock
|
Mouser Part #
838-L31S300S05FS
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 300A;+5V;VREFOUT)
|
|
400In Stock
|
|
|
₡8 306,63
|
|
|
₡6 188,33
|
|
|
₡5 964,53
|
|
|
₡5 407,64
|
|
|
View
|
|
|
₡5 100,56
|
|
|
₡4 715,42
|
|
|
₡4 684,19
|
|
|
₡4 476,00
|
|
|
₡4 356,30
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
Hall Effect Current Sensor
|
300 A
|
|
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 100A; +5V)
- L37S100S05M
- Tamura
-
1:
₡7 635,23
-
160In Stock
|
Mouser Part #
838-L37S100S05M
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 100A; +5V)
|
|
160In Stock
|
|
|
₡7 635,23
|
|
|
₡6 937,80
|
|
|
₡6 682,78
|
|
|
₡6 453,77
|
|
|
View
|
|
|
₡6 073,83
|
|
|
₡5 626,23
|
|
|
₡5 621,03
|
|
|
₡5 308,75
|
|
|
₡5 168,22
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
|
|
|
|
|
|
Board Mount Current Sensors FLUX-GATE CS VREFOUT ( 50A; +5V)
- F03P050S05L
- Tamura
-
1:
₡7 604,00
-
256In Stock
|
Mouser Part #
838-F03P050S05L
|
Tamura
|
Board Mount Current Sensors FLUX-GATE CS VREFOUT ( 50A; +5V)
|
|
256In Stock
|
|
|
₡7 604,00
|
|
|
₡6 911,78
|
|
|
₡6 656,75
|
|
|
₡6 349,68
|
|
|
View
|
|
|
₡6 073,83
|
|
|
₡5 855,24
|
|
|
₡5 542,96
|
|
|
₡5 251,50
|
|
|
₡5 183,84
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
|
|
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 3A; 15V)
- L18P003D15
- Tamura
-
1:
₡5 641,84
-
1 023In Stock
|
Mouser Part #
838-L18P003D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 3A; 15V)
|
|
1 023In Stock
|
|
|
₡5 641,84
|
|
|
₡4 377,11
|
|
|
₡4 205,36
|
|
|
₡3 684,90
|
|
|
View
|
|
|
₡3 539,16
|
|
|
₡3 216,48
|
|
|
₡2 951,04
|
|
|
₡2 867,76
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
3 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 50A; 15V)
- L18P050D15
- Tamura
-
1:
₡6 032,19
-
456In Stock
|
Mouser Part #
838-L18P050D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 50A; 15V)
|
|
456In Stock
|
|
|
₡6 032,19
|
|
|
₡4 705,01
|
|
|
₡4 522,84
|
|
|
₡3 903,49
|
|
|
View
|
|
|
₡3 747,35
|
|
|
₡3 528,76
|
|
|
₡3 393,43
|
|
|
₡3 154,02
|
|
|
₡3 039,52
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
50 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 6A; +5V)
- S22P006S05
- Tamura
-
1:
₡7 931,89
-
397In Stock
|
Mouser Part #
838-S22P006S05
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 6A; +5V)
|
|
397In Stock
|
|
|
₡7 931,89
|
|
|
₡6 687,98
|
|
|
₡6 214,36
|
|
|
₡5 641,84
|
|
|
View
|
|
|
₡5 246,29
|
|
|
₡4 871,56
|
|
|
₡4 600,91
|
|
|
₡4 340,68
|
|
|
₡4 220,97
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
6 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 400A; +5V)
- L01Z400S05
- Tamura
-
1:
₡7 770,55
-
175In Stock
-
200Expected 10/23/2026
|
Mouser Part #
838-L01Z400S05
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 400A; +5V)
|
|
175In Stock
200Expected 10/23/2026
|
|
|
₡7 770,55
|
|
|
₡7 078,33
|
|
|
₡6 896,17
|
|
|
₡6 521,43
|
|
|
View
|
|
|
₡6 292,43
|
|
|
₡6 245,58
|
|
|
₡5 891,67
|
|
|
₡5 641,84
|
|
|
₡5 595,00
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
400 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 500A; +5V)
- L01Z500S05
- Tamura
-
1:
₡10 138,67
-
274In Stock
|
Mouser Part #
838-L01Z500S05
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 500A; +5V)
|
|
274In Stock
|
|
|
₡10 138,67
|
|
|
₡7 744,53
|
|
|
₡7 442,66
|
|
|
₡6 750,44
|
|
|
View
|
|
|
₡6 354,88
|
|
|
₡5 870,85
|
|
|
₡5 756,35
|
|
|
₡5 563,78
|
|
|
₡5 454,48
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
500 A
|
|
0 Hz to 100 kHz
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 500A; 15V)
- L34S500D15T
- Tamura
-
1:
₡15 733,67
-
72In Stock
|
Mouser Part #
838-L34S500D15T
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 500A; 15V)
|
|
72In Stock
|
|
|
₡15 733,67
|
|
|
₡14 422,10
|
|
|
₡13 506,08
|
|
|
₡12 303,80
|
|
|
View
|
|
|
₡11 866,61
|
|
|
₡11 720,88
|
|
|
₡11 715,68
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
|
|
|
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 100A; 15V)
- L08P100D15
- Tamura
-
1:
₡6 427,75
-
513In Stock
|
Mouser Part #
838-L08P100D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 100A; 15V)
|
|
513In Stock
|
|
|
₡6 427,75
|
|
|
₡5 360,79
|
|
|
₡5 038,11
|
|
|
₡4 574,89
|
|
|
View
|
|
|
₡4 226,18
|
|
|
₡3 950,33
|
|
|
₡3 945,13
|
|
|
₡3 346,59
|
|
|
₡3 341,39
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
100 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 25A; +5V)
- S22P025S05
- Tamura
-
1:
₡8 254,58
-
671In Stock
|
Mouser Part #
838-S22P025S05
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 25A; +5V)
|
|
671In Stock
|
|
|
₡8 254,58
|
|
|
₡6 823,30
|
|
|
₡6 469,38
|
|
|
₡5 808,39
|
|
|
View
|
|
|
₡5 345,18
|
|
|
₡5 012,08
|
|
|
₡4 632,14
|
|
|
₡4 356,30
|
|
|
₡4 288,63
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
25 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 150A; 15V)
- L08P150D15
- Tamura
-
1:
₡6 427,75
-
62In Stock
-
500Expected 12/1/2026
|
Mouser Part #
838-L08P150D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 150A; 15V)
|
|
62In Stock
500Expected 12/1/2026
|
|
|
₡6 427,75
|
|
|
₡5 423,25
|
|
|
₡5 038,11
|
|
|
₡4 574,89
|
|
|
View
|
|
|
₡4 538,46
|
|
|
₡3 788,99
|
|
|
₡3 216,48
|
|
|
₡3 211,27
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
150 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 50A; 15V; 1000T)
- S25P050D15X
- Tamura
-
1:
₡10 778,84
-
6In Stock
-
300Expected 3/31/2027
|
Mouser Part #
838-S25P050D15X
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 50A; 15V; 1000T)
|
|
6In Stock
300Expected 3/31/2027
|
|
|
₡10 778,84
|
|
|
₡9 087,33
|
|
|
₡8 447,15
|
|
|
₡7 666,46
|
|
|
View
|
|
|
₡7 125,17
|
|
|
₡6 032,19
|
|
|
₡5 553,37
|
|
|
₡5 501,32
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
50 A
|
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors FLUX-GATE CS VREFOUT( 25A; +5V)
- F03P025S05L
- Tamura
-
1:
₡7 421,84
-
7In Stock
|
Mouser Part #
838-F03P025S05L
|
Tamura
|
Board Mount Current Sensors FLUX-GATE CS VREFOUT( 25A; +5V)
|
|
7In Stock
|
|
|
₡7 421,84
|
|
|
₡6 740,03
|
|
|
₡6 490,20
|
|
|
₡6 188,33
|
|
|
View
|
|
|
₡5 980,15
|
|
|
₡5 355,59
|
|
|
₡4 876,76
|
|
|
₡4 783,08
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
|
|
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 50A; 15V)
- L03S050D15
- Tamura
-
1:
₡8 806,27
-
109In Stock
|
Mouser Part #
838-L03S050D15
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 50A; 15V)
|
|
109In Stock
|
|
|
₡8 806,27
|
|
|
₡7 427,04
|
|
|
₡6 901,37
|
|
|
₡6 266,40
|
|
|
View
|
|
|
₡5 824,01
|
|
|
₡5 412,84
|
|
|
₡5 022,49
|
|
|
₡4 626,94
|
|
|
₡4 538,46
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
Hall Effect Current Sensor
|
50 A
|
1 %
|
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 25A; 15V)
- L07P025D15
- Tamura
-
1:
₡9 128,96
-
23In Stock
|
Mouser Part #
838-L07P025D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 25A; 15V)
|
|
23In Stock
|
|
|
₡9 128,96
|
|
|
₡7 702,89
|
|
|
₡7 156,40
|
|
|
₡6 495,41
|
|
|
View
|
|
|
₡6 037,40
|
|
|
₡5 792,78
|
|
|
₡5 058,92
|
|
|
₡4 731,03
|
|
|
₡4 642,55
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
25 A
|
|
0 Hz to 100 kHz
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 1000A; 24V; 5000T)
- S29S1T0D24Z
- Tamura
-
1:
₡99 101,82
-
8In Stock
|
Mouser Part #
838-S29S1T0D24Z
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 1000A; 24V; 5000T)
|
|
8In Stock
|
|
|
₡99 101,82
|
|
|
₡75 810,99
|
|
|
₡73 005,68
|
|
|
₡70 689,61
|
|
|
View
|
|
|
₡70 096,28
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
Hall Effect Current Sensor
|
1 kA
|
0.4 %
|
0 Hz to 100 kHz
|
|
|
|
Board Mount Current Sensors FLUX-GATE CS VREFOUT ( 50A; +5V)
- F03P050S05
- Tamura
-
1:
₡10 450,95
-
292In Stock
|
Mouser Part #
838-F03P050S05
|
Tamura
|
Board Mount Current Sensors FLUX-GATE CS VREFOUT ( 50A; +5V)
|
|
292In Stock
|
|
|
₡10 450,95
|
|
|
₡8 811,48
|
|
|
₡8 186,92
|
|
|
₡7 432,25
|
|
|
View
|
|
|
₡6 906,58
|
|
|
₡6 422,54
|
|
|
₡5 787,58
|
|
|
₡5 485,71
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
50 A
|
0.7 %
|
200 kHz to 300 kHz
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 600A; 15V)
- L34S600D15T
- Tamura
-
1:
₡16 217,70
-
43In Stock
|
Mouser Part #
838-L34S600D15T
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 600A; 15V)
|
|
43In Stock
|
|
|
₡16 217,70
|
|
|
₡14 333,62
|
|
|
₡13 480,05
|
|
|
₡12 454,74
|
|
|
View
|
|
|
₡11 877,02
|
|
|
₡11 668,83
|
|
|
₡11 465,85
|
|
|
₡11 460,65
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
|
|
|
|
|
|
|
Board Mount Current Sensors CURRENT SENSOR ( 15A; 15V)
- L18P015D15
- Tamura
-
1:
₡5 735,53
-
194In Stock
-
600Expected 4/13/2027
|
Mouser Part #
838-L18P015D15
|
Tamura
|
Board Mount Current Sensors CURRENT SENSOR ( 15A; 15V)
|
|
194In Stock
600Expected 4/13/2027
|
|
|
₡5 735,53
|
|
|
₡4 835,12
|
|
|
₡4 491,62
|
|
|
₡4 080,45
|
|
|
View
|
|
|
₡3 788,99
|
|
|
₡3 523,55
|
|
|
₡3 117,59
|
|
|
₡2 888,58
|
|
|
₡2 852,15
|
|
Min.: 1
Mult.: 1
|
|
Board Mount Current Sensors
|
|
15 A
|
|
0 Hz to 100 kHz
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 1500A; 15V)
- L34S1T5D15
- Tamura
-
1:
₡21 698,20
-
43In Stock
|
Mouser Part #
838-L34S1T5D15
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 1500A; 15V)
|
|
43In Stock
|
|
|
₡21 698,20
|
|
|
₡18 294,36
|
|
|
₡15 983,49
|
|
|
₡14 557,42
|
|
|
View
|
|
|
₡13 943,27
|
|
|
₡13 719,47
|
|
|
₡13 714,26
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
Hall Effect Current Sensor
|
1.5 kA
|
|
|
|
|
|
Current Sensors - Industrial CURRENT SENSOR ( 800A; 15V)
- L34S800D15
- Tamura
-
1:
₡20 454,29
-
51In Stock
|
Mouser Part #
838-L34S800D15
|
Tamura
|
Current Sensors - Industrial CURRENT SENSOR ( 800A; 15V)
|
|
51In Stock
|
|
|
₡20 454,29
|
|
|
₡17 248,22
|
|
|
₡16 030,33
|
|
|
₡14 042,16
|
|
|
View
|
|
|
₡13 063,68
|
|
|
₡12 829,47
|
|
|
₡12 501,58
|
|
|
Quote
|
|
Min.: 1
Mult.: 1
|
|
Industrial Current Sensors
|
Hall Effect Current Sensor
|
800 A
|
|
|
|